Abstract
Continuous heart-rate (HR) monitoring from wrist-worn photoplethysmography (PPG) is central to consumer and clinical wearable devices, yet motion artefact remains the principal obstacle to reliable estimation during daily activity. This study develops and rigorously evaluates a motion-aware, feature-based machine-learning pipeline for HR estimation from synchronised wrist PPG and tri-axial accelerometry, using the publicly available PPG-DaLiA dataset (15 participants, Empatica E4 wrist sensor, ECG-derived reference HR). Eight-second, two-second-shifted windows were constructed from the deposited signals (64,697 windows retained), and eighteen spectral and time-domain descriptors were extracted from the PPG and acceleration-magnitude spectra. Three regression models (ridge regression, Extra-Trees, histogram-based gradient boosting) were compared under five-fold, participant-grouped cross-validation restricted to a development partition of ten participants, the Extra-Trees regressor was selected by out-of-fold participant-macro mean absolute error (MAE) and frozen before any exposure to the five held-out test participants. On the untouched test partition, the frozen model achieved an MAE of 14.12 bpm (95% participant-clustered bootstrap CI, reported in-text) against a deterministic spectral-peak baseline's MAE of 24.61 bpm, a mean improvement of 10.49 bpm (95% CI −18.41 to −4.02), with concordance correlation coefficient (CCC) of 0.567 versus 0.193 for the baseline. Permutation importance identified the dominant PPG spectral peak frequency, secondary PPG peak, and PPG spectral entropy as the leading predictors. An exploratory one-dimensional convolutional neural network (CNN), trained only for comparison and never permitted to replace the frozen classical model, achieved a lower test MAE of 10.93 bpm, suggesting head-room for representation-learning approaches while confirming that the engineered-feature pipeline provides a robust, computationally inexpensive, and fully auditable alternative. All modelling decisions were made without access to the test partition, and a leakage audit confirmed no participant overlap between partitions. These results quantify, with participant-independent rigour and calibrated uncertainty, the accuracy achievable by classical ensemble learning on engineered spectral features for wrist-PPG heart-rate estimation, and they identify motion artefact — rather than model capacity — as the primary remaining source of error.
Keywords
Photoplethysmography, Heart-Rate Estimation, Wearable Sensors, Motion Artefact, Extra-Trees, PPG-Dalia, Feature Engineering, Participant-Independent Validation,Downloads
References
- P.H. Charlton, J. Allen, R. Bailón, S. Baker, J.A. Behar, F. Chen, G.D. Clifford, D.A. Clifton, H.J. Davies, C. Ding, X. Ding, J. Dunn, M. Elgendi, M. Ferdoushi, D. Franklin, E. Gil, M.F. Hassan, J. Hernesniemi, X. Hu, N. Ji, Y. Khan, S. Kontaxis, I. Korhonen, P.A. Kyriacou, P. Laguna, J. Lázaro, C. Lee, J. Levy, Y. Li, C. Liu, J. Liu, L. Lu, D.P. Mandic, V. Marozas, E. Mejía-Mejía, R. Mukkamala, M. Nitzan, T. Pereira, C.C.Y. Poon, J.C. Ramella-Roman, H. Saarinen, M.M.H. Shandhi, H. Shin, G. Stansby, T. Tamura, A. Vehkaoja, W.K. Wang, Y.T. Zhang, N. Zhao, D. Zheng, T. Zhu, The 2023 wearable photoplethysmography roadmap. Physiological Measurement, 44(11), (2023) 111001.
- B. Bent, B.A. Goldstein, W.A. Kibbe, J.P. Dunn. Investigating sources of inaccuracy in wearable optical heart rate sensors. NPJ Digital Medicine, 3, (2020) 18.
- Z. Zhang, Z. Pi, B. Liu, TROIKA: A general framework for heart rate monitoring using wrist-type photoplethysmographic signals during intensive physical exercise. IEEE Transactions on Biomedical Engineering, 62(2), (2015) 522–531.
- Z. Zhang, Photoplethysmography-based heart rate monitoring in physical activities via joint sparse spectrum reconstruction. IEEE Transactions on Biomedical Engineering, 62(8), (2015) 1902–1910.
- A. Reiss, I. Indlekofer, P. Schmidt, & K. Van Laerhoven. (2019). Deep PPG: Large-scale heart rate estimation with convolutional neural networks. Sensors, 19(14), Article 3079.
- A. Reiss, I. Indlekofer, P. Schmidt. (2019). PPG-DaLiA [Dataset]. UCI Machine Learning Repository.
- M. Wilkosz, A. Szczęsna. Multi-headed Conv-LSTM network for heart rate estimation during daily living activities. Sensors, 21(15), (2021) 5212.
- P. Geurts, D. Ernst, L. Wehenkel, Extremely randomized trees. Machine Learning, 63(1), (2006) 3–42.
- J.H. Friedman, Greedy function approximation: A gradient boosting machine. The Annals of Statistics, 29(5), (2001) 1189–1232.
- J.M. Bland, D.G. Altman, Statistical methods for assessing agreement between two methods of clinical measurement. The Lancet, 327(8476), (1986) 307–310.
- L.I.K. Lin. A concordance correlation coefficient to evaluate reproducibility. Biometrics, 45(1), (1989) 255–268.
- L. Breiman. Random forests. Machine Learning, 45(1), (2001) 5–32.
- A. Fisher, C. Rudin, F. Dominici, All models are wrong, but many are useful: Learning a variable's importance by studying an entire class of prediction models simultaneously. Journal of Machine Learning Research, 20(177), (2019) 1–81.
- B. Efron, Bootstrap methods: Another look at the jackknife. The Annals of Statistics, 7(1), (1979) 1–26.
- F. Pedregosa, G. Varoquaux, A. Gramfort, V. Michel, B. Thirion, O. Grisel, M. Blondel, P. Prettenhofer, R. Weiss, V. Dubourg, J. Vanderplas, A. Passos, D. Cournapeau, M. Brucher, M. Perrot, É. Duchesnay, Scikit-learn: Machine learning in Python. Journal of Machine Learning Research, 12(85), (2011) 2825–2830.
Articles
