Abstract
In this study, we present a new and straightforward graphene-zinc sulfide (ZnS) nanocomposite that we've successfully created for use in a carbon paper-based cholesterol biosensor. By integrating ZnS nanoparticles onto graphene sheets, we've significantly enhanced the electrocatalytic performance of the electrode, which boosts the sensitivity of the cholesterol biosensor. We carried out a comprehensive analysis of the nanocomposite's structure and components using techniques like XRD, SEM, and TEM. For detecting cholesterol, we immobilized cholesterol oxidase onto the ZnS/G modified carbon paper electrode. Our cyclic voltammetry (CV) analysis indicated that there’s direct electron transfer happening between the enzyme and the electrode. The biosensor we developed showcased a quick response time, impressive sensitivity, a wide linear detection range, and a low detection limit. Plus, the ZnS/G modified carbon paper electrode proved to be highly selective, consistently reproducible, and stable for over a month.
Keywords
ZnS, Biosensor, Nanoparticles, XRD, SEM, TEM,Downloads
References
- A.D. Ambaye, K.K. Kefeni, S.B. Mishra, E.N. Nxumalo, B. Ntsendwana, Recent developments in nanotechnology-based printing electrode systems for electrochemical sensors. Talanta, 225, (2021) 121951. https://doi.org/10.1016/j.talanta.2020.121951
- M. Baharfar, M. Rahbar, M. Tajik, G. Liu, Engineering strategies for enhancing the performance of electrochemical paper-based analytical devices. Biosensors and Bioelectronics, 167, (2020) 112506. https://doi.org/10.1016/j.bios.2020.112506
- A. Kumar, R.R. Pandey, B. Brantley, Tetraethylorthosilicate film modified with protein to fabricate cholesterol biosensor. Talanta, 69(3), (2006) 700-705. https://doi.org/10.1016/j.talanta.2005.11.003
- S.K. Arya, P.R. Solanki, R.P. Singh, M.K. Pandey, M. Datta, B.D. Malhotra, Application of octadecanethiol self-assembled monolayer to cholesterol biosensor based on surface plasmon resonance technique. Talanta, 69(4), (2006) 918-926. https://doi.org/10.1016/j.talanta.2005.11.037
- E. Solhi, M. Hasanzadeh, P. Babaie, Electrochemical paper-based analytical devices (ePADs) toward biosensing: recent advances and challenges in bioanalysis. Analytical Methods, 12(11), (2020) 1398-1414. https://doi.org/10.1039/D0AY00117A
- S.P. Martin, D.J. Lamb, J.M. Lynch, S.M. Reddy, Enzyme-based determination of cholesterol using the quartz crystal acoustic wave sensor. Analytica Chimica Acta, 487(1), (2003) 91-100. https://doi.org/10.1016/S0003-2670(03)00504-X
- A.A. Ansari, A. Kaushik, P.R. Solanki, B.E. Malhotra, Electrochemical cholesterol sensor based on tin oxide‐chitosan nanobiocomposite film. Electroanalysis: An International Journal Devoted to Fundamental and Practical Aspects of Electroanalysis, 21(8), (2009) 965-972. https://doi.org/10.1002/elan.200804499
- C. Charan, V.K. Shahi, Nanostructured manganese oxide–chitosan-based cholesterol sensor. Journal of Applied Electrochemistry, 44, (2014) 953-962. https://doi.org/10.1007/s10800-014-0704-0
- C.C. Allain, L.S. Poon, C.S. Chan, W.F.P.C. Richmond, P.C. Fu, Enzymatic determination of total serum cholesterol. Clinical chemistry, 20(4), (1974) 470-475. https://doi.org/10.1093/clinchem/20.4.470
- J.A.T.L. MacLachlan, A.T.L. Wotherspoon, R.O. Ansell, C.J.W. Brooks, Cholesterol oxidase: sources, physical properties and analytical applications. The Journal of steroid biochemistry and molecular biology, 72(5), (2000) 169-195. https://doi.org/10.1016/S0960-0760(00)00044-3
- S. Singh, A. Chaubey, B.D. Malhotra, Preparation and characterization of an enzyme electrode based on cholesterol esterase and cholesterol oxidase immobilized onto conducting polypyrrole films. Journal of applied polymer science, 91(6), (2004) 3769-3773. https://doi.org/10.1002/app.13554
- J.C. Vidal, J. Espuelas, J.R. Castillo, Amperometric cholesterol biosensor based on in situ reconstituted cholesterol oxidase on an immobilized monolayer of flavin adenine dinucleotide cofactor. Analytical biochemistry, 333(1), (2004) 88-98. https://doi.org/10.1016/j.ab.2004.06.005
- S.K. Arya, P. Pandey, S.P. Singh, M. Datta, B.D. Malhotra, Dithiobissuccinimidyl propionate self assembled monolayer based cholesterol biosensor. Analyst, 132(10), (2007) 1005-1009. https://doi.org/10.1039/B707000D
- A. Kumar, R.R. Pandey, B. Brantley, Tetraethylorthosilicate film modified with protein to fabricate cholesterol biosensor. Talanta, 69(3), (2006) 700-705. https://doi.org/10.1016/j.talanta.2005.11.003
- S. Brahim, D. Narinesingh, A. Guiseppi-Elie, Amperometric determination of cholesterol in serum using a biosensor of cholesterol oxidase contained within a polypyrrole–hydrogel membrane. Analytica chimica acta, 448(1-2), (2001) 27-36. https://doi.org/10.1016/S0003-2670(01)01321-6
- S. Singh, A. Chaubey, B.D. Malhotra, Amperometric cholesterol biosensor based on immobilized cholesterol esterase and cholesterol oxidase on conducting polypyrrole films. Analytica chimica acta, 502(2), (2004) 229-234. https://doi.org/10.1016/j.aca.2003.09.064
- X. Tan, M. Li, P. Cai, L. Luo, X. Zou, An amperometric cholesterol biosensor based on multiwalled carbon nanotubes and organically modified sol-gel/chitosan hybrid composite film. Analytical Biochemistry, 337(1), (2005) 111-120. https://doi.org/10.1016/j.ab.2004.10.040
- J.C. Vidal, J. Espuelas, E. Garcia-Ruiz, J.R. Castillo, Amperometric cholesterol biosensors based on the electropolymerization of pyrrole and the electrocatalytic effect of Prussian-Blue layers helped with self-assembled monolayers. Talanta, 64(3), (2004) 655-664. https://doi.org/10.1016/j.talanta.2004.03.038
- Z. Matharu, G. Sumana, S.K. Arya, S.P. Singh, V. Gupta, B.D. Malhotra, Polyaniline Langmuir− Blodgett film based cholesterol biosensor. Langmuir, 23(26), (2007) 13188-13192. https://doi.org/10.1021/la702123a
- P.R. Solanki, S. Singh, N. Prabhakar, M.K. Pandey, B.D. Malhotra, Application of conducting poly (aniline‐co‐pyrrole) film to cholesterol biosensor. Journal of applied polymer science, 105(6), (2007) 3211-3219. https://doi.org/10.1002/app.26198
- S. Singh, P.R. Solanki, M.K. Pandey, B.D. Malhotra, Covalent immobilization of cholesterol esterase and cholesterol oxidase on polyaniline films for application to cholesterol biosensor. Analytica Chimica Acta, 568(1-2), (2006) 126-132. https://doi.org/10.1016/j.aca.2005.10.008